| Model | MS3012 |
| Measurement Geometry | 12 measurement angles (7 illumination sources, 2 receivers) |
| Measure Angle | 45° Receiver: 45as-15°,45as15°,45as25°, 45as45°,45as75°,45as110° 15°Receiver: 15as-45°,15as-15°,15as15°, 15as-30°,15as45°,15as80° Conform to the standards:ASTM D 2244,E 308,E 1164,E 2194, E2539,DIN 5033,5036,6174,6175-1,6175-2;ISO 7724, 11664-4 SAE J 1545 |
| Application | Provide accurate and consistent color measurement for metallic, pearlescent and other complex special effect color products |
| Light Source | Full spectrum LED light source with blue enhancement |
| Lamp Life | 5 years, 3 million times measurements |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 400nm-700nm |
| Wavelength Interval | 10nm |
| Measurement Range | 0~600% |
| Semiband Width | 10nm |
| Measuring Aperture | Illumination size Φ23mm / Measuring spot 9X12mm (Customized: Illumination size Φ10mm / Measuring spot 6X8mm) |
| Color Space | CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99 |
| Color Difference Formula | ΔE*ab,ΔE*94,ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE DIN6175,color difference formulas of multiple car brands |
| Other Colorimetric Index | Flop Index, Int-Em |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75, F1,F2(CWF),F3,F4,F5,F6, F7(DLF),F8,F9,F10(TPL5), F11(TL84),F12(TL83/U30) |
| Display | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color simulation, Sample effect value, Effect difference value |
| Measuring Time | (not including the effective color measuring time) |
| Repeatability | Spectral reflectance: Standard deviation within 0.08% Chromaticity value: ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
| Reproducibility | ΔE*<0.10,avg on the gray tile of BCRA tile set ΔE*<0.25,avg on the color BCRA tile set |
| Inter-instrument Error | 0.18ΔE*00(avg on reference Series II BCRA tile set) |
| Effect Parameters | Sparkle Grade(SG),Diffuse coarseness(DC) and Color Variation(CV) |
| Effect Measurement | 6 angles Sparkle Grade(SG),Color Variation(CV):15as-45°,15as-30°,15as-15°,15as15°,15as45°,15as80° 15d Diffuse coarseness(DC) |
| Effect Repeatability | Sparkle Grade(SG) Short-term repeatability: 0.12% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration) Diffuse coarseness(DC) Short-term repeatability:e0.09% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration) |
| Effect Reproducibility | Sparkle Grade(SG) Reproducibility: 1.9% (10 times standard deviations) (avg on reference Series II BCRA tile set) Diffuse coarseness(DC) Reproducibility: 1.4% (10 times standard deviations)(avg on reference Series II BCRA tile set) |
| Trigger mode | Pressure sensing trigger, button trigger, software trigger |
| Measuring Mode | Single measurement, average measurement (1-99), continuous measurement (1-99) |
| Locating Mode | Color camera preview |
| Dimension | L*W*H=195X83X128mm |
| Weight | About 1Kg |
| Power | lithium-ion battery, 3.7V,5000mAh, Continuous test 6000 times within 8 hours of full charge |
| Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
| Interface | USB, Bluetooth 5.0 |
| Data Storage | 1000 pcs Standards,4000 pcs Samples |
| Language | Simplified Chinese, Traditional Chinese, English |
| Operating Environment | 10℃ to 50℃, humidity does not exceed 85%, no condensation |
| Storage Environment | -20℃ to 50℃, humidity does not exceed 85%, no condensation |
| Calibration | Built-in white board parameters, external white board, black light trap, color board |
| Calibration Interval | 4 hours,8 hours,24 hours,Startup calibration |
| Standard accessories | Power Adapter, USB Cable, User Guide,PC Software(download from the official website), Calibration Board, black light trap,Protective cap, wristband |
| Optional Accessory | Micro-printer |
| Notes | Technical parameters are for reference only, subject to actual sales products. |
Analytical Instruments
MS3012 Multi-angle spectrophotometer
Capture Color from Every Angle
Multi angle precision spectrophotometer MS30 series automotive surface paint metal color pearl paint particle size hardware plastic color difference detector, which is especially suitable for color measurement of special effect finishes like metallic and pearlescent paints
At a Glance:
- 7 illumination sources and 2 receivers to simultaneously measure 12 specific angles
- 256-pixel dual-array CMOS image sensor and concave grating spectrophotometric technology
- Colorimetric repeatability ΔEab can be controlled within 0.02, and it meets the requirements of national first-class metrology
- Blue-enhanced full-spectrum LED light source, which avoids spectral loss of conventional LEDs in specific wavelength bands.
- Directly display comprehensive data such as spectral graphs, chromaticity values, color difference values and graphs, pass/fail results, and color simulations.
✓ Requirement-Based Sourcing▤ Documentation Support◎ Technical Assistance
Product Documents
Datasheets, manuals, calibration documents, COA/SDS or related technical documents are available where applicable to the selected product and manufacturer.
Need a specific document? Add this product to your RFQ Basket and mention the required document in the item notes.